 Click image to enlarge
            Click image to enlarge
         
        
     
 
    
         The 
 V-PLEX platform  offers analytically validated singleplex and multiplex assay kits. Developed under rigorous design control, V-PLEX kits provide accurate and reproducible results with consistency from lot to lot. The V-PLEX Plus Human Cytokine 35-Plex Kit includes 35 biomarkers associated with the inflammatory response and immune system regulation (Table 1). The assays can be used for quantitative measurements in the sample types listed in the “Specifications” tab below and offer detection limits (LLODs and LLOQs) in the sub- to low pg/mL range.
    
 
	
    
    
    
    
	
		| Analyte | LLOD | LLOQ | ULOQ | Dynamic Range | Unit | 
	
		| Eotaxin | 0.20 | 2.14 | 910 | 0.20 - 910 | pg/mL | 
	
		| Eotaxin-3 | 1.44 | 11.1 | 11,100 | 1.44 - 11,100 | pg/mL | 
	
		| GM-CSF | 0.16 | 0.842 | 750 | 0.16 - 750 | pg/mL | 
	
		| IFN-γ | 0.37 | 1.76 | 938 | 0.37 - 938 | pg/mL | 
	
		| IL-1α | 0.09 | 2.85 | 278 | 0.09 - 278 | pg/mL | 
	
		| IL-1β | 0.05 | 0.646 | 375 | 0.05 - 375 | pg/mL | 
	
		| IL-2 | 0.09 | 0.89 | 938 | 0.09 - 938 | pg/mL | 
	
		| IL-4 | 0.02 | 0.218 | 158 | 0.02 - 158 | pg/mL | 
	
		| IL-5 | 0.14 | 4.41 | 562 | 0.14 - 562 | pg/mL | 
	
		| IL-6 | 0.06 | 0.633 | 488 | 0.06 - 488 | pg/mL | 
	
		| IL-7 | 0.12 | 0.851 | 563 | 0.12 - 563 | pg/mL | 
	
		| IL-8 | 0.07 | 0.591 | 375 | 0.07 - 375 | pg/mL | 
	
		| IL-10 | 0.04 | 0.298 | 233 | 0.04 - 233 | pg/mL | 
	
		| IL-12/IL-23p40 | 0.33 | 1.32 | 2,250 | 0.33 - 2,250 | pg/mL | 
	
		| IL-12p70 | 0.11 | 1.22 | 315 | 0.11 - 315 | pg/mL | 
	
		| IL-13 | 0.24 | 4.21 | 353 | 0.24 - 353 | pg/mL | 
	
		| IL-15 | 0.15 | 0.774 | 525 | 0.15 - 525 | pg/mL | 
	
		| IL-16 | 2.83 | 19.1 | 1,870 | 2.83 - 1,870 | pg/mL | 
	
		| IL-17A | 0.31 | 3.19 | 3,650 | 0.31 - 3,650 | pg/mL | 
	
		| IL-17A Gen. B | 0.413 | 5.86 | 1,950 | 0.413 - 1,950 | pg/mL | 
	
		| IL-21 | 0.193 | 6.12 | 650 | 0.193 - 650 | pg/mL | 
	
		| IL-22 | 0.27 | 2.78 | 325 | 0.27 - 325 | pg/mL | 
	
		| IL-23 | 0.274 | 4.6 | 3,250 | 0.274 - 3,250 | pg/mL | 
	
		| IL-27 | 4.2 | 38.7 | 13,000 | 4.20 - 13,000 | pg/mL | 
	
		| IL-31 | 0.446 | 4.22 | 650 | 0.446 - 650 | pg/mL | 
	
		| IP-10 | 0.12 | 1.29 | 1,240 | 0.12 - 1,240 | pg/mL | 
	
		| MCP-1 | 0.16 | 1.45 | 247 | 0.16 - 247 | pg/mL | 
	
		| MCP-4 | 0.05 | 0.518 | 234 | 0.05 - 0.518 | pg/mL | 
	
		| MDC | 1.00 | 6.43 | 2,930 | 1.00 - 2,930 | pg/mL | 
	
		| MIP-1α | 0.05 | 0.357 | 403 | 0.05 - 403 | pg/mL | 
	
		| MIP-1β | 0.09 | 1.20 | 390 | 0.09 - 390 | pg/mL | 
	
		| MIP-3α | 0.05 | 0.75 | 325 | 0.050 - 325 | pg/mL | 
	
		| TARC | 0.11 | 2.14 | 481 | 0.11 - 481 | pg/mL | 
	
		| TNF-α | 0.04 | 0.69 | 248 | 0.04 - 248 | pg/mL | 
	
		| TNF-β | 0.08 | 0.465 | 458 | 0.08 - 458 | pg/mL | 
	
		| VEGF-A | 1.12 | 7.7 | 562 | 1.12 - 562 | pg/mL | 
 
    
    
    
        
                
            
                - 
                    
                
- 
                    Specifications
                
- 
                    
                
- 
                    Documentation
                
- 
                    References
                
            
                    
                    
                
                    
                    
                        
	
    
            
        
            
                | Application(s) |  | Cytokines & Chemokines
                        , 
                            Immunology/Inflammation |  | 
        
            
                | Analyte(s) |  | Eotaxin, Eotaxin-3, GM-CSF, IFN-γ, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-10, IL-12/IL-23p40, IL-12p70, IL-13, IL-15, IL-16, IL-17A, IL-21, IL-22, IL-23, IL-27, IL-31, IP-10, MCP-1, MCP-4, MDC, MIP-1α, MIP-1β, MIP-3α, TARC, TNF-α, TNF-β, VEGF-A |  | 
        
            
                | Species |  | Human |  | 
        
            
                | Plate Type |  | 96-well |  | 
        
            
                | Instrument(s) |  | MESO SECTOR S 600MM
                        , 
                            MESO QuickPlex SQ 120MM
                        , 
                            MESO SECTOR S 600
                        , 
                            MESO QuickPlex SQ 120
                        , 
                            SECTOR Imager 6000
                        , 
                            SECTOR Imager 2400 |  | 
        
            
                | Sample Type |  | Serum, Plasma, Cell Culture Supernatant, Urine |  | 
        
            
                | Usage Statement |  | For Research Use Only. Not for use in diagnostic procedures. |  | 
        
            
                | Storage Statement(s) |  | Please refer to the product insert for the storage conditions of individual kit components. |  | 
        
            
                | Storage Condition |  | Multi-Component |  | 
        
            
                | Schedule B Code |  | 3822.19.0000 |  | 
        
            
        
 
                     
                
                    
                    
                        
                    
                
                    
                    
                
                    
                    
                        
	
    
        
            
                | Title | Journal | Year |  | 
            
                    
                        | A phase 1 study of prophylactic anakinra to mitigate ICANS in patients with large B-cell lymphoma 
 |  |  |   | 
                
                    
                        | Twenty-eight day repeated exposure of human 3D bronchial epithelial model to heated tobacco aerosols indicates decreased toxicological responses compared to cigarette smoke 
 |  |  |   | 
                
                    
                        | Viral Antigen and Inflammatory Biomarkers in Cerebrospinal Fluid in Patients With COVID-19 Infection and Neurologic Symptoms Compared With Control Participants Without Infection or Neurologic Symptoms 
 |  |  |   | 
                
                    
                        | Characterization and Biomarker Analyses of Post-COVID-19 Complications and Neurological Manifestations 
 |  |  |   | 
                
                    
                        | Galectin-9, a Player in Cytokine Release Syndrome and a Surrogate Diagnostic Biomarker in SARS-CoV-2 Infection 
 |  |  |   | 
                
            
                | View All | 
        
    
 
                     
                
         
     
 
    
    
 
 
    
    
    
    
        
    
    
    
            
            Customer Service/Orders
            
            
            
            
            
            
            
        
            
            Scientific/Technical Support
            
            
            
            
            
            
            
        
            
            Instrument Support
            
            
            
            
            
            
            
        
            
            Company Headquarters