MSD Contact Information Legal Terms MSD Jobs
MESO SCALE DISCOVERY
MESO SCALE DISCOVERY
Catalog
MULTI-ARRAY Detection Technology
Products
Literature & Publications
Applications Literature
Brochures
Customer Presentations
MSD Assay Product Inserts
Technical & Application Notes
MSD Publication References
Our Company
Purchase MSD Assays
Shows & Events We Attend
 



Publications

High-Throughput Simultaneous Analysis of RNA, Protein, and Lipid Biomarkers in Heterogeneous Tissue Samples.

Reiser, V., Smith, R.C., Xue, J., Kurtz, M.M., Liu, R., Legrand, C., He, X., Yu, X., Wong, P., Hinchcliffe, J.S., Tanen, M.R., Lazar, G., Zieba, R., Ichetovkin, M., Chen, Z., O'Neill, E.A., Tanaka, W.K., Marton, M.J., Liao, J., Morris, M., Hailman, E., Tokiwa, G.Y., Plump, A.S.

Journal Clin Chem. Year 2011
Species Human Volume 57 (11)
CD68, CRP, ICAM-1, IL-1β, IL-6, MCP-1, MIP-1α, Myeloperoxidase, RANTES, TNF-RII Page # 1545-1555
Matrix Tested Tissue homogenate supernatants Cytokines & Chemokines

Abstract

BACKGROUND: With expanding biomarker discovery efforts and increasing costs of drug development, it is critical to maximize the value of mass-limited clinical samples. The main limitation of available methods is the inability to isolate and analyze, from a single sample, molecules requiring incompatible extraction methods. Thus, we developed a novel semiautomated method for tissue processing and tissue milling and division (TMAD).

METHODS: We used a SilverHawk atherectomy catheter to collect atherosclerotic plaques from patients requiring peripheral atherectomy. Tissue preservation by flash freezing was compared with immersion in RNAlater®, and tissue grinding by traditional mortar and pestle was compared with TMAD. Comparators were protein, RNA, and lipid yield and quality. Reproducibility of analyte yield from aliquots of the same tissue sample processed by TMAD was also measured.

RESULTS: The quantity and quality of biomarkers extracted from tissue prepared by TMAD was at least as good as that extracted from tissue stored and prepared by traditional means. TMAD enabled parallel analysis of gene expression (quantitative reverse-transcription PCR, microarray), protein composition (ELISA), and lipid content (biochemical assay) from as little as 20 mg of tissue. The mean correlation was r = 0.97 in molecular composition (RNA, protein, or lipid) between aliquots of individual samples generated by TMAD. We also demonstrated that it is feasible to use TMAD in a large-scale clinical study setting.

CONCLUSIONS: The TMAD methodology described here enables semiautomated, high-throughput sampling of small amounts of heterogeneous tissue specimens by multiple analytical techniques with generally improved quality of recovered biomolecules.

View Publication


Related Products
Human Chemokine 7-Plex Ultra-Sensitive Kit
Human Chemokine 9-Plex Base Kit
Human Chemokine 9-Plex Tissue Culture Kit
Human Chemokine 9-Plex Ultra-Sensitive Kit
Human Demonstration 10-Plex Base Kit
Human Demonstration 10-Plex Tissue Culture Kit
Human Demonstration 4-Plex Base Kit
Human Demonstration 4-Plex Tissue Culture Kit
Human Demonstration 7-Plex Base Kit
Human Demonstration 7-Plex Tissue Culture Kit

view more

Suggest a Reference


Speak with a Scientist



CAREERS     |     CONTACT US     |     LEGAL     |     PRIVACY
Feedback Form
Feedback Analytics